Uimp = 4 kV
UOC MAX = 1000 V
≤ Up = 4 kV
II
InC = 30 AThe sum of the IB must not be greater than InA.
InA = 30 A
Itotal (8/20 µs) = 40 kA
RDF = 1
MC4
| Type of cable | Quantity | Length | Cross-section |
|---|---|---|---|
| incoming | 2 | 500 mm | 6 mm² |
| Maximum number of conductors clamping units each | Conductor cross-section min. | Conductor cross-section max. | Conductor cross section | Conductor type | Conductor material |
|---|---|---|---|---|---|
| 1 | 1.5 mm² | 16 mm² | solid, stranded, flexible | round | Cu |
Tool operation
cover
stainless steel mounting plate for wall and post installations
IP65
IK08
ready for connection
Indoor installation
35 °C
-5 °C up to +40 °C
≤ 50 % at 40 °C, ≤ 100 % at 25 °C
Polycarbonate
Yes
Yes
210 mm
200 mm
111 mm
2.56 kg
transparent
DIN EN IEC 61439
61001083
4012591116929
1
85369010
DYNAMIC: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-8.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-7.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-6.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-5.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-4.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
Insulation-enclosed box-type low-voltage switchgear in accordance with IEC 61439-1 forsurface-mounting on walls. Enclosures must be suitable for the outdoor installation, however the climatic influences and effects on the equipment are to be considered. Enclosure bottom parts and lids made from impact resistant polycarbonate, halogen- and silicone-free Colour RAL 7035, with transparent lid. Burning behaviour in accordance with DIN VDE 0471 Part 2 Glow wire test 960° C. Protective measure: total insulation (protection class II). Make: HENSEL KV.
PV generator junction box with DC surge arrester type 2, for 1x PV string to 1x inverter input. Degree of protection according to IEC 60529: IP 65. Dimensions HxWxD 210 x 200 x 111 mm