Ui = 690 V
In = 32 A
| Maximum number of conductors clamping units each | Conductor cross-section min. | Conductor cross-section max. | Conductor cross section | Conductor type | Conductor material |
|---|---|---|---|---|---|
| 4 | 1.5 mm² | 1.5 mm² | solid, stranded, flexible | round | Cu |
| 3 | 2.5 mm² | 2.5 mm² | solid, stranded, flexible | round | Cu |
| 2 | 4 mm² | 4 mm² | solid, stranded, flexible | round | Cu |
| 1 | 6 mm² | 6 mm² | solid, stranded, flexible | round | Cu |
2
Screw connection
No
10 mm
0.7 Nm
| Number of cable entries | Type of cable entry | Size of the metric knockouts | Sealing range of the cable entry | Position of cable entry |
|---|---|---|---|---|
| 7 | elastic membranes | M20, M25 | 9 mm - 17 mm | wall |
| 1 | elastic membranes | without | 6 mm - 15 mm | bottom |
Quick locking: opening and closing by quarter turn, locked position well visible (open - locked)
external brackets, retaining strap, sealing plug
IP66
IK07
Yes
Indoor installation
35 °C
-25 °C up to +40 °C
≤ 50 % at 40 °C, ≤ 100 % at 25 °C
Polypropylene
750 °C
V-2
-25 °C up to +80 °C
Yes
Yes
104 mm
104 mm
70 mm
0.158 kg
DIN EN 60670-1/-22, IEC 60670-1/-22
| Type of certificate | Certificate number |
|---|---|
| VDE | 40049684 |
62000004
4012591124962
5
85369010
DYNAMIC: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-8.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-7.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-6.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-5.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-4.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
Cable junction boxes in accordance with IEC 60670-22 with built-in connecting terminal and removable elastic sealing membranes. Suitable for indoor and protected outdoor installation in accordance with DIN VDE 0100, part 737. For ambient temperatures of max. +40°C and min. -25°C, relative humidity 50% at +40°C or 100% at +25°C. Material temperature resistance from -25°C to +70°C, burning behaviour in accordance with VDE 0471, part 2 – glow wire test 750°C, UL Subject 95 V-2. Degree of protection in accordance with IEC 60529: IP 66. Rated insulation voltage: 690 V. Material: thermoplastic, halogen and silicon free. Colour: grey, RAL 7035. Lid fastening with quick fasteners, sealable without accessories. Plug-in external brackets for wall mounting included. Make: HENSEL ENYCASE DK.
Nominal cross-section: 1.5-4 mm², 5-pole terminal, dimensions HxWxD 104 x 104 x 70 mm