Ui = 400 V
In = 100 A
5
Screw connection
Yes
| Maximum number of conductors clamping units each | Conductor cross-section min. | Conductor cross-section max. | Conductor cross section | Conductor type | Conductor material |
|---|---|---|---|---|---|
| 1 | 16 mm² | 35 mm² | solid, stranded | round | Cu |
| 1 | 10 mm² | 25 mm² | flexible with end ferrule | round | Cu |
| Maximum number of conductors clamping units each | Conductor cross-section min. | Conductor cross-section max. | Conductor cross section | Conductor type | Conductor material |
|---|---|---|---|---|---|
| 1 | 10 mm² | 25 mm² | solid, stranded | round | Cu |
| 1 | 6 mm² | 16 mm² | flexible with end ferrule | round | Cu |
| Number of cable entries | Type of cable entry | Size of the metric knockouts | Position of cable entry |
|---|---|---|---|
| 10 | metric knockouts | M25, M40, M50 | wall |
| 2 | metric knockouts | M32 | bottom |
Quick locking: opening and closing by quarter turn, locked position well visible (open - locked)
external brackets, sealing plug
IP66IP degree of protection of the included Grommets 3x ESM 40: IP55, sealing range 17 mm - 30 mm
IK07
Yes
Indoor installation
35 °C
-25 °C up to +40 °C
≤ 50 % at 40 °C, ≤ 100 % at 25 °C
Polycarbonate
750 °C
V-2
-25 °C up to +80 °C
Yes
Yes
225 mm
295 mm
122 mm
1.659 kg
DIN EN 60670-1/-22, IEC 60670-1/-22
62000169
4012591125600
1
85369010
DYNAMIC: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-8.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-7.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-6.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-5.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
ETIM-4.0: EC002600 - Box/housing for surface mounting on the wall/ceiling
Cable junction boxes with built-in main line branch terminal and metric knockouts. Suitable for indoor and protected outdoor installation in accordance with DIN VDE 0100, part 737. For ambient temperatures maximum value +40 °C and minimum value -25 °C, with relative humidity of 50 % at +40 °C or 100 % at +25 °C. Material temperature resistance of -25 °C to +70 °C, burning behaviour according to IEC 60695-2-11 - glow wire test 750 °C, UL Subject 94 V-2. Degree of protection in accordance with IEC 60529: IP 66 with AKM cable glands. Rated insulation voltage: 400 V a.c. Material: thermoplastics, halogen- and silicone-free. Colour: grey RAL 7035. Lid fastening with quick fasteners, sealable without accessories. Plug-in external brackets for wall mounting included. Make: HENSEL ENYCASE DK.
Rated cross-section: 6x 6-35 mm², 4-pole terminal, dimensions HxWxD 225 x 295 x 122 mm