In safety-relevant areas such as escape routes, fire compartments, or technical operating rooms, the functional integrity of electrical systems is crucial. The ENYCASE FK series was specially developed for these requirements and meets the highest standards regarding fire protection and operational safety.
To ensure that these systems continue to operate reliably in the event of fire, junction boxes with defined functional integrity are indispensable. They ensure that electrical connections remain operational even under extreme heat exposure – and this for a specified period of time. In Germany, DIN 4102-12 regulates the requirements for the functional integrity of electrical cable systems. These are divided into the classes E30, E60, and E90, which define functional integrity for 30, 60, and 90 minutes, respectively. Additionally, insulation integrity in accordance with BS EN 50200 (PH 120) is a crucial safety factor. It ensures that electrical insulation is maintained even under intense heat exposure – a must for critical infrastructures.
For electrical specialist companies, this means: Only products that demonstrably offer functional integrity or insulation integrity guarantee maximum operational safety and standard-compliant installation. Rely on certified quality – for maximum safety you can depend on in an emergency.

Thanks to the independent protection of the models FK 1604 1F/2F, the functional integrity of the main line is also ensured in the event of fire.
Thanks to the integrated fuse, the entire main line remains intact in the event of a short circuit – without an additional distribution unit. This saves space and costs and meets the standard requirements for functional integrity in the event of fire.

With a secured outgoing line (1F), a single safety-relevant system, such as an emergency lighting system, can be protected.

With two secured outgoing lines (2F), two separate loads can be protected without an additional distribution unit.

Safety lighting and emergency power supply

Fire compartments and escape routes

Industrial facilities with increased fire protection requirements

Public buildings
With metric knockouts for cable entry up to 16 mm². Tested for use with functional integrity E 30 / 60 / 90 or insulation integrity in accordance with BS EN 50200. Screw anchors, high-temperature resistant ceramic terminal, and cable entries are included as standard in the scope of delivery.
Junction boxes for large cross-sections up to 50 mm². Tested for use with functional integrity E 30 / 60 / 90 or insulation integrity in accordance with BS EN 50200. Protection against accidental contact is ensured by the enclosure. Mounting via external wall fastening. Communication distributor E30 for the installation of various telecommunications connection strips.
Our experts will assist you further:
Do you require assistance in selecting the appropriate junction box or have questions regarding installation? Our specialists will support you.
In our product information, you will find all technical details summarized in detail.