Un = 400 V
| Rated insulation voltage | Voltage type |
|---|---|
| Ui = 690 V | a.c. |
II
In = 101 A
No
| power dissipation capability Pde | Temperature difference |
|---|---|
| Pde = 13 W | 30 K |
| Number of clamping units per pole | Connection type |
|---|---|
| 4 | Plug-in terminal connection |
| 2 | Screw connection |
| Maximum number of conductors clamping units each | Conductor cross-section min. | Conductor cross-section max. | Conductor cross section | Conductor type | Conductor material |
|---|---|---|---|---|---|
| 1 | 1.5 mm² | 4 mm² | solid, flexible | round | Cu |
| Maximum number of conductors clamping units each | Conductor cross-section min. | Conductor cross-section max. | Conductor cross section | Conductor type | Conductor material |
|---|---|---|---|---|---|
| 4 | 1.5 mm² | 2.5 mm² | solid | round | Cu |
| 1 | 1.5 mm² | 25 mm² | flexible | round | Cu |
| 3 | 4 mm² | 6 mm² | solid | round | Cu |
| 1 | 10 mm² | 10 mm² | solid | round | Cu |
| 1 | 16 mm² | 25 mm² | stranded | round | Cu |
| Number of cable entries | Type of cable entry | Sealing range of the cable entry | Position of cable entry |
|---|---|---|---|
| 4 | elastic membranes | 7 mm - 16 mm | wall top+bottom |
| 2 | elastic membranes | 10 mm - 20 mm | wall top+bottom |
| 1 | elastic membranes | 10 mm - 24 mm | wall top+bottom |
cover
Yes
6 modules
1
sealing plug, DIN rail(s), labelling strips, cable entry cover
IP54
Break out
Indoor installation
35 °C
-5 °C up to +40 °C
≤ 50 % at 40 °C, ≤ 100 % at 25 °C
Polystyrene
750 °C
V-2
-25 °C up to +80 °C
Yes
Yes
238 mm
146 mm
111 mm
0.743 kg
EN 60670-1, DIN EN 60670-24
61000735
4012591107064
1
85381000
DYNAMIC: EC000214 - Small distribution board
ETIM-8.0: EC000214 - Small distribution board
ETIM-7.0: EC000214 - Small distribution board
ETIM-6.0: EC000214 - Small distribution board
ETIM-5.0: EC000214 - Small distribution board
ETIM-4.0: EC000214 - Small distribution board
Small-type distribution boards in accordance with DIN EN 60670-24 and IEC 61439-3, for the installation of DIN rail equipment up to 63 A in accordance with DIN 43880, protectively insulated (protection class II). Suitable for indoor use and protected outdoor installation in accordance with DIN VDE 0100, Part 737. For ambient temperature max. +40 °C and min. -5 °C, at relative humidity 50% at +40 °C or 100% at -25 °C. Material temperature resistance from -40 °C to +70 °C. Flammability according to VDE 0471, Part 2 - glow-wire test 750 °C, UL Subject 94 V-2. Rated voltage: 400 V. Material: thermoplastic, halogen- and silicone-free. Color: grey, RAL 7035 with transparent cover. Manufacturer: HENSEL KV.
Degree of protection: IP 54 with integrated, elastic membranes. 6 modules of 18 mm each. Dimensions HxWxD 238 x 146 x 111 mm.